Last reviewed:
PSI to GPM Calculator
Pressure alone doesn’t tell you the flow. The same 60 psi gives about 14.2 GPM through a 1/4-inch nozzle and about 226.5 GPM through a 1-inch one. So this calculator asks what the water flows through. Use Nozzle / Opening when water leaves through a nozzle, a hole, or an open hose end and you know the pressure right at it. Use Through a Pipe when you know how much pressure you can lose along a run of pipe. Both give GPM, LPM, and water velocity.
Results
Estimates only. Assumes clean water at about 60°F (16°C) and a full, steady flow. Pipe mode ignores fittings, valves, and elevation change, which all take extra pressure. Confirm against a flow test or your supplier's data before sizing pumps, irrigation zones, or fire systems. TakeoffCalc isn't responsible for sizing errors.
How to use this calculator
- 01Pick Nozzle / Opening if water leaves through a nozzle, a hole, or an open hose end. Pick Through a Pipe if you want the flow a length of pipe can carry.
- 02For a nozzle or opening, enter the opening diameter and the pressure right at it while water is flowing, then pick the opening type.
- 03For a pipe, enter the pressure you can afford to lose, the pipe length, the material, and the size.
- 04Read the flow in GPM and LPM at the top of the results, along with the water velocity.
- 05In pipe mode, if a velocity note shows up, try the next pipe size up.
Understanding the math
Nozzle / Opening mode uses the standard discharge equation for water leaving a round opening. It comes from Q = Cd × A × √(2gh), with the pressure turned into feet of water head (2.31 ft per psi) and the result turned into gallons per minute.
GPM = 29.84 × Cd × d² × √P
d = opening diameter (inches)
P = pressure at the opening while flowing (psi)
Cd = discharge coefficient
0.98 smooth or rounded nozzle
0.62 sharp-edged holeWorked example. A smooth 1/2-inch nozzle at 60 psi: 29.84 × 0.98 × 0.5² × √60 = 56.6 GPM. The same size drilled hole with a sharp edge passes 35.8 GPM, because the jet necks down just past the edge.
Through a Pipe mode uses the Hazen-Williams equation for water, solved for flow. Friction in the pipe uses up the pressure, so the flow depends on how much pressure you can spare, how long the pipe is, its inside diameter, and how smooth it is (the C value).
loss (psi per ft) = 4.52 × Q^1.852 ÷ (C^1.852 × d^4.87) Solved for flow: Q = (loss × C^1.852 × d^4.87 ÷ 4.52)^(1 ÷ 1.852) Q = flow (GPM) d = inside diameter (inches) loss = pressure drop ÷ pipe length
Worked example. 100 feet of 3/4-inch Schedule 40 PVC (inside diameter 0.804 in, C 150) with 10 psi to spare: the loss is 10 ÷ 100 = 0.1 psi per foot, and the flow comes out to 10.8 GPM at 6.8 ft/s.
Assumptions: clean water at about 60°F (16°C), a full pipe, and steady flow. Pipe mode ignores fittings, valves, and elevation change. Velocity is the flow divided by the area of the opening or pipe. Metric inputs are converted to inches, feet, and psi before the math runs, and the results are converted back.
Flow through a smooth opening
Flow through a smooth, round nozzle (Cd 0.98) by opening size and flowing pressure. For a sharp-edged hole, multiply by about 0.633.
| Opening | 20 psi | 40 psi | 60 psi | 80 psi |
|---|---|---|---|---|
| 1/8 in | 2 GPM | 2.9 GPM | 3.5 GPM | 4.1 GPM |
| 1/4 in | 8.2 GPM | 11.6 GPM | 14.2 GPM | 16.3 GPM |
| 3/8 in | 18.4 GPM | 26 GPM | 31.9 GPM | 36.8 GPM |
| 1/2 in | 32.7 GPM | 46.2 GPM | 56.6 GPM | 65.4 GPM |
| 5/8 in | 51.1 GPM | 72.2 GPM | 88.5 GPM | 102.2 GPM |
| 3/4 in | 73.6 GPM | 104 GPM | 127.4 GPM | 147.1 GPM |
| 1 in | 130.8 GPM | 185 GPM | 226.5 GPM | 261.6 GPM |
Flow through 100 feet of pipe
Flow through 100 ft (30.5 m) of straight pipe with a 10 psi (68.9 kPa) pressure drop, using the inside diameter shown under each flow. Many of these run above the velocity guideline, so check the calculator before you size a line.
| Size | PVC (C 150) | PEX (C 150) | Copper (C 140) | Steel, new (C 120) | Galvanized steel, old (C 100) |
|---|---|---|---|---|---|
| 1/2 in | 5 GPMID 0.602 in | 2.7 GPMID 0.475 in | 3.6 GPMID 0.545 in | 4.4 GPMID 0.622 in | 3.7 GPMID 0.622 in |
| 3/4 in | 10.8 GPMID 0.804 in | 6.7 GPMID 0.671 in | 9.5 GPMID 0.785 in | 9.2 GPMID 0.824 in | 7.7 GPMID 0.824 in |
| 1 in | 20.7 GPMID 1.029 in | 13 GPMID 0.863 in | 19.1 GPMID 1.025 in | 17.4 GPMID 1.049 in | 14.5 GPMID 1.049 in |
| 1-1/4 in | 43 GPMID 1.36 in | — | 33.2 GPMID 1.265 in | 35.8 GPMID 1.38 in | 29.8 GPMID 1.38 in |
| 1-1/2 in | 64.9 GPMID 1.59 in | — | 52.4 GPMID 1.505 in | 53.6 GPMID 1.61 in | 44.7 GPMID 1.61 in |
| 2 in | 126 GPMID 2.047 in | — | 108.5 GPMID 1.985 in | 103.4 GPMID 2.067 in | 86.2 GPMID 2.067 in |
Frequently asked questions
Can you convert PSI to GPM?
Not from pressure alone. PSI is how hard the water pushes; GPM is how much moves. The same pressure gives very different flows depending on what the water goes through. At 60 psi, a smooth 1/4-inch opening passes about 14.2 GPM and a smooth 1-inch opening about 226.5 GPM. Push 60 psi through 100 feet of 3/4-inch PVC and you get about 28.4 GPM, because the pipe uses up the pressure along the way.
So a PSI to GPM answer always needs the opening size or the pipe size, length, and material. That's what the two modes above ask for.
Which mode should I use?
Use Nozzle / Opening when water leaves through a nozzle, a drilled hole, or an open hose or pipe end, and you know the pressure right at that opening while it flows. Use Through a Pipe when you know the pressure at the start of a pipe run and the pressure you need at the far end, such as a line from a well tank to a barn or a sprinkler zone.
How many GPM is 60 psi through a 1/2-inch opening?
About 56.6 GPM through a smooth nozzle (Cd 0.98) and about 35.8 GPM through a sharp-edged drilled hole (Cd 0.62), with 60 psi measured at the opening while it flows. A 1/2-inch garden hose delivers much less than that, because the hose and faucet use up most of the pressure before the water reaches the end.
What pressure should I enter for a nozzle?
The pressure at the nozzle while water is flowing. A gauge on a closed hose bib reads static pressure, and that drops once water starts moving. Using static pressure overstates the flow. Fire crews measure flowing pressure at the tip with a pitot gauge for the same reason.
What C value should I use for my pipe?
The Hazen-Williams C value describes how smooth the inside of the pipe is. This calculator uses PVC 150, PEX 150, copper 140, new steel 120, and old galvanized steel 100. Steel loses C as it rusts and scales inside, so use the old galvanized value for pipe that has been in service for years. If you have a value from an engineer or a manufacturer, pick Custom C.
Why does the calculator warn about velocity?
Fast water is noisy, wears fittings, and makes water hammer worse when a valve closes. A common guideline is to stay under about 5 ft/s in plastic pipe and 8 ft/s in metal pipe. For example, 10 psi over 100 feet of 3/4-inch PVC moves 10.8 GPM at 6.8 ft/s, which is over the plastic guideline. A larger pipe carries the same flow more slowly.
What does the pipe mode leave out?
It assumes clean water at about 60°F (16°C) filling a straight pipe. It ignores fittings, valves, meters, and elevation change. Each foot the pipe climbs costs about 0.433 psi, so subtract that from the pressure drop you enter. Elbows and valves add more loss, so treat the result as the most the pipe can carry.
Related calculators
Gallons Per Minute Calculator
Measure real flow with a bucket and a stopwatch, or convert another flow unit to GPM.
Tank Fill Time Calculator
Turn a flow rate into the time it takes to fill or drain a tank.
Pipe Volume Calculator
Find how many gallons a pipe run holds from its inside diameter and length.
Liters Per Minute Calculator
Convert LPM to GPM and other flow units, or measure LPM from a bucket fill.